    Fire Suppression Systems

    GAS Suppression System ( Gaseous Agent ): Gaseous fire suppression is a term to describe the use of inert gases and chemical agents to extinguish a fire. The system typically consists of the agent, agent storage containers, agent release valves, fire detectors, fire detection system (wiring control panel, actuation signalling), agent delivery piping, and agent dispersion nozzles. Less typically, the agent may be delivered by means of solid propellant gas generators that produce either inert or chemically active gas. These Agents are governed by the NFPA Standard for Clean Agent Fire Extinguishing Systems When it comes to protecting the information and hardware in a datacenter. Gaseous fire suppression systems have some obvious advantages. People choose gaseous systems is because they don’t want water all over their computer systems. The system typically consists of the agent, agent storage containers, agent release valves, fire detectors, fire detection system (wiring control panel, actuation signalling), agent delivery piping, and agent dispersion nozzles. Less typically, the agent may be delivered by means of solid propellant gas generators that produce either inert or chemically active gas.

    Merits of gas based fire suppression system

    • Fast and effective against a wide range of Class A, B and electrical fires.
    • Safe for occupied areas.
    • Non-corrosive and electrically non-conductive.
    • No post-discharge residue and clean-up.
    • Environmentally acceptable.
    • 25 / 42 bar system
    • Range of system release options.
    • Low installation and maintenance costs.
    • Computer design maximizes effectiveness of system. Clean agent Gas based Fire suppression system shall comply the international standards like BS 6266, NFPA 2001 and NFPA 72E. We design the gas quantity, piping layout for your datacenter room and prepare BOQ to install. A proper testing of all loops is done before putting it in auto mode.

    Analog Addressable Fire Alarm System

    This type of installation gives each detector on a system an individual number, or address. Thus, analog addressable detectors allow a fire alarm control panel, and therefore fire fighters, to know the exact location of an alarm. In certain systems, a graphical representation of the building is provided and the exact location of the alarm can indicated on the diagram. Analog addressable systems are usually more expensive than conventional non-addressable systems, and offer extra options, such as a custom level of sensitivity(sometimes called Day/Night mode) and contamination detection from the main panel that allows determination of a wide range of faults. Panels can also be interconnected to control a very large number of detectors in many other buildings commonly used in hospitals, universities, resorts and similar large centers.
    ManTech offer supply, Installation, testing, commissioning as well as maintenance services for all types of fire alarm panels, smoke detector, heat detector, carbon monoxide detector (CO) , carbon dioxide detector, combi-detectors, multi-criteria detectors, control and monitor modules, isolator modules, hooters & strobes, Manual call points.